Skip to main content

9. Network Technical Specifications

AirQo Binos Monitor Specifications

Sampling FrequencyEvery 10 minutes (6 readings/hour, 144 readings/day)
Power SourceSolar-powered with battery backup
ConnectivityIoT-enabled (cellular/WiFi) for real-time data transmission
DeploymentOutdoor ambient air monitoring
Lifespan3 years with basic maintenance (extendable with component replacement)
Sensor TechnologyOptical particle counters for PM measurements

Network Performance Metrics

Uptime Target>85% (20+ hours of data daily)
Expected Readings/Day144 per monitor
Good Performance>75% completeness (>108 readings/day)
Minimum for Analysis50% completeness (>72 readings/day)

Maintenance Requirements

  • Routine Maintenance — Minimum every 6 months. Clean solar panels and clear sensor inlets of dust/debris using a clean cloth and hand blower.
  • Laser Sensor Lifetime — Approximately 2 years. Smart power management extends operational life.
  • Component Replacement — Monitors can be recalled for component upgrades and refurbishment.